Aerial Bundled Cable (ABC Cable)
Aerial Bundled Cable (ABC Cable)
Aerial Bundled Cable (ABC Cable)
Aerial Bundled Cable (ABC Cable)
Aerial Bundled Cable (ABC Cable)

Aerial Bundled Cable (ABC Cable)

Application

Used primarily for overhead and distribution line,or to supply 120/220V aerial service for tem service at construction sites,as a service drop(power pole to service entrance)as a secondary cable(Pole to Pole),or street lighting.For service at 1000V or lower at a maximum conductor temperature of 75℃ or 90℃.

Applicable Standards

ANSI/ICEAS-70-547,ANSI/ICEA S-76-474,NFC 33-209,IEC60502-1,BS7870.50,VDE 027-626 GB/T12527 SANS1418or the standards agreed by both of the customers and us.

  • Application
  • Construction
  • Parameter
  • Message

Application

Used primarily for overhead and distribution line,or to supply 120/220V aerial service for tem service at construction sites,as a service drop(power pole to service entrance)as a secondary cable(Pole to Pole),or street lighting.For service at 1000V or lower at a maximum conductor temperature of 75℃ or 90℃.

Applicable Standards

ANSI/ICEAS-70-547,ANSI/ICEA S-76-474,NFC 33-209,IEC60502-1,BS7870.50,VDE 027-626 GB/T12527 SANS1418or the standards agreed by both of the customers and us.

Production Scope:

Voltage:1KV and below.
Phase Core: 1 to 6 Cores,Cross section from 6AWG to 500MCM.
Bare Neutral: Cross Section from 6AWG to 500MCM.

Construction

  • Phase Core:
  • Conductor: Hard bare copper/Aluminum/Aluminum alloy etc.
  • Insulation: PVC/XLPE/PE
  • Neutral Conductor(optional): ACSR /AAAC/AAC
  • Insulation: PVC/XLPE/PE
  • Street Lighting core(optional):
  • Conductor: AAC
  • Insulation: PVC/XLPE/PE
  • *We can design and produce according to client's requirement.

Technical Characteristics

  • ABC/NFC33-209
  • ABC/ICEA S-76-474

Number of Cores x

Nominal Cross

Section,No.x  mm²

Nominal Thickness of Insulation mm

Approx Overall

Diameter

mm

Approx.mass

Kg/Km

Maximum

Conductor

Resistance

Ω/Km

 

Minimum Breaking Load,KN

 

Current

Rating A

Phase

core

Neutral

core

Lighting

core

2×16

1.2

1.2

-

15

130

1.91

 

2.3

93

2×16+2×1.5

1.2

1.2

-

16

175

1.91/12.1

4×16

1.2

1.2

-

18

260

1.91

83

4×16+2×1.5

1.2

1.2

 

20

310

1.91/12.1

2×25

1.4

1.4

-

18

202

1.2

 

3.8

122

2×25+2×1.5

1.4

1.4

-

19.5

250

1.2/12.1

4×25

1.4

1.4

-

22

404

1.2

111

4×25+2×1.5

1.4

1.4

-

24

452

1.2/12.1

3×35+1×54.6+K×16

(K can be 0,1,2,3)

1.6

1.6

1.2

28.5/29.5/31/33

620/685/750/815

0.868/0.63/1.91

 

 

16.6

138/83

3×50+1×54.6+K×16

(K can be 0,1,2,3)

1.6

1.6

1.2

30.5/32.5/34/36

740/805/870/935

0.641/0.63/1.91

165/83

3×70+1×54.6+K×16

(K can be 0,1,2,3)

1.8

1.6

1.2

34.5/36/39/41

975/1040/1105/1170

0.868/0.63/1.91

213/83

3×95+1×70+K×16

(K can be 0,1,2,3)

1.8

1.5

1.2

37/39.5/42/44

1210/1275/1340/1405

0.32/0.50/1.91

 

20.5

258/83

3×120+1×70+K×16

(K can be 0,1,2,3)

1.8

1.5

1.2

38.5/40.5/43.5/46

1477/1542/1607/1672

0.253/0.50/1.91

 

3×120+1×95+K×16

(K can be 0,1,2,3)

1.8

1.6

1.2

39.5/41.5/44.5/47

1535/1600/1665/1730

0.253/0.343/1.91

27.5

 

3×150+1×70+K×16

(K can be 0,1,2,3)

 

1.7

 

1.5

 

1.2

 

40.5/42/44.5/48

 

1755/1820/1885/1950

 

0.206/0.50/1.91

 

20.5

 

 

344/83

3×150+1×95+K×16

(K can be 0,1,2,3)

1.7

1.6

1.2

43.2/45.3/47/49

1832/1897/1961/2026

0.206/0.343/1.91

27.5

Item#

 

Phase

Conductor

AWG

Phase

Conductor Insulation

mil

Bare Neutral

Messenger

Size

AWG

Bare

Neutral  Messenger Breaking

Strength Ib

Weight Per

1000ft-

XLPE

Ib

 

Weight Per

100Oft-PE

Ib

Ampacity-

XLPE

A

Ampacity-

XLPE

A

Voluta

6

45

6

1190

120

130

85

70

Periwinkle

4

45

4

1860

176

172

115

90

Conch

2

45

2

2850

267

261

150

120

Neritina

1/0

60

1/0

4380

426

419

205

160

Triton

2/0

60

2/0

5310

530

519

235

185

Cherrystone

3/0

60

3/0

6620

656

643

250

200

Razor

4/0

60

4/0

8350

814

799

315

245

Limpet

336.4

80

336.4

8680

1209

1167

420

325